METAL LINE

Radiant baffle

METAL LINE radiant heating and cooling baffles combine thermal activation with acoustic effectiveness. The vertical arrangement of the metal baffles provides a comparatively large thermally and acoustically effective surface area.

The system is also suitable for retrofitting existing buildings. Thanks to simple installation, the radiant heating and cooling baffles can be integrated into different room situations and combined with various design requirements.

An acoustic fleece is integrated into the baffle for sound absorption. For higher acoustic requirements, an additional insulation insert can be provided.
  • Thermal comfort according to EN ISO 7730, SIA 382/1
  • Building material class B-s2, d0 according to EN 13501-1
  • Very high heating and cooling capacity
  • Acoustically effective (class C)
  • Easy to install
  • Suitable for retroactive installation
  • Available in various colours and surfaces, including wood-look finishes
  • Components can be integrated
Contact us
Cooling capacity
> 150 W/m² (8 K)

Kühlleistung 5

Heating capacity
> 100 W/m² (15 K)

Heizleistung 4

Sound absorption
Class C

Schallabsorption 3

Carbon footprint
< 75 kg CO2/m²

CO2-Bilanz 3

Cooling capacity

The cooling capacity corresponds to the amount of energy per second removed from the room via heat radiation and convection. It is determined in accredited climate laboratories in accordance with SN EN 14240.

For comparison: the heat emitted by a person in an office via radiation and convection is approx. 70 – 80 W; the heat emitted by a laptop is approx. 20 – 50 W.

Heating capacity

The heating capacity corresponds to the energy per second added to the room via heat radiation and convection. It is determined in accredited climate laboratories in accordance with SN EN 14037.

For comparison: The heat output of a person in an office via radiation and convection is approx. 70 – 80 W, whilst that of a laptop is approx. 20 – 50 W.

Sound absorption

As the largest unobstructed surface in a room, the ceiling is particularly well suited to sound absorption. The sound absorption class is determined in accordance with EN ISO 11654, based on measurements carried out in accordance with EN ISO 354 in accredited laboratories.

It serves as a parameter for acoustic designers to calculate the effect of a product on a room’s reverberation time.

Carbon footprint

The carbon footprint describes the greenhouse gas emissions associated with a product. These emissions are expressed as CO₂ equivalents. The life cycle stages considered are specified in the respective Environmental Product Declaration and its defined system boundaries.

An Environmental Product Declaration (EPD) transparently presents various environmental impacts of a product based on a life cycle assessment. The calculation is carried out in accordance with the standards and methodological requirements specified in the EPD. Where stated, the EPD is verified by an independent third party.

Ceiling system

open

Operating principle

Convection

Air supply

visible

Capacity (water)

  • Cooling: up to 24 W/lm (ΔT: 8 K)
    Active area ratio: 90 %
  • Heating: up to 27 W/lm (ΔT: 15 K)

Acoustics

αw: up to 0,75
Sound absorption class C
(EN ISO 11654)

Room comfort

Thermal comfort according to